介绍DS1847用于工业控制-Introduction of

abstract: this application note introduces the ds1847 and ds1848, dual digital temperature-controlled variable resistors, to the industrial controls market. by temperature compensating the resistors, the resistors can either remain at a specific resistance or vary over temperature by programming a unique resistor value every 2°c. the ds1847 can also be used to control voltage or current. the ds1847 and ds1848 are identical except the ds1848 includes additional user programmable eeprom. in this application note, ds1847 will refer to the ds1847 and ds1848.
this application note presents the ds1847 features and operation in addition to some application ideas. to discuss how the ds1847 can benefit your application, please contact applications support at mixedsignal.apps@dalsemi.com.
ds1847 featuresfigure 1 shows a block diagram of the ds1847. the ds1847 operates from a 3v or 5v supply over the temperature range of -40°c to +95°c and offers internal closed loop temperature compensation.
figure 1. block diagram.
the ds1847 can operate standalone in closed loop mode without a microcontroller or with a microcontroller using an optional 2-wire master. the 2-wire master allows multiple devices to be controlled in different locations.
figure 2 shows how multiple ds1847s can be connected to a 2-wire master. the address pins allow up to 8 devices on the 2-wire bus.
figure 2. 2-wire interface.
temperature compensationone of the benefits of the ds1847 is the internal closed loop temperature compensation. since the resistor settings and memory are nonvolatile, a microprocessor is not needed when using the ds1847.
with the ability to program the resistance as a function of temperature, the user can create a very low tempco resistor. the compensated tempco error is ±4 lsb. a transfer function can be programmed into the resistor lookup table (lut) to fit many applications. the resistor lut is eeprom memory that can contain a unique resistor value at a specific temperature from -40°c to +95°c in 2°c increments. see the ds1847 operation section for more information on the lut.
the resistor outputs can also be used as digital outputs to drive external circuitry. the outputs can be used as alarms or as general-purpose digital outputs. the ds1847 can be configured to output a resistance, voltage, or current.
ds1847 operationthe ds1847 has a lut that determines the resistor value at a specific temperature (see figure 3). first, after a 10ms conversion time, the internal temperature sensor senses the ambient temperature. this temperature determines the lut address. if the temperature sensed is -38°c, the corresponding address is 01h. the resistance value in address location 01h is used to adjust the resistance.
figure 3. lookup table.
using the ds1847 with industrial controlsthe ds1847 can be beneficial in industrial control applications. first, the temperature-controlled resistor can provide a relatively constant resistance over temperature or the resistance can be set to increase or decrease with temperature.
figure 4 shows how the ds1847 can be connected to a fixed resistor to create a voltage divider (vout0). this will provide a fixed or variable output voltage to an application over temperature. a transfer function can be programmed into the lut to change the voltage with temperature.
figure 4. voltage and digital outputs.
the ds1847 can also be configured to create a digital output (vout1). using a fixed resistance of 4.7kω and the 50kω variable resistor, the output voltage range is 0.77v to 4.57v (see example 1). the digital output can be used as an alarm or warning when the temperature reaches a certain value (see the voltage alarm example). the digital output can be set to go low or high if the temperature changes from the set value or if the temperature exceeds a certain value.
voltage alarm examplesto set the voltage to go high when a specific temperature is reached, 94°c in this illustration (see figure 5), the lut would be programmed to set the resistor to the minimum position (position 0) for the temperature range -40°c to 92°c. for temperatures 94°c and above the resistor position would be set to ffh.
figure 5. lookup table for a voltage alarm.
design considerationswhen using the ds1847 as a voltage divider or a digital output, the fixed resistor value needs to be calculated (see figure 6).
example 1.
if the ds1847 will be configured as a digital output, the output voltage needs to meet the vih and vil levels of the digital circuitry. equation 1 shows how to calculate the output voltage at a certain fixed resistance.
equation 1
where, vin = vcc = 5v
rv = ds1847 50kω resistor (rmin = 850ω, rmax = 50kω)
(notice that the minimum resistance at position 0 is not 0ω but 850ω.)
rf = fixed resistor
figure 6. voltage divider.
using equation 1 and the rmin and rmax of the 50kω resistor, the output voltage range is calculated.
using a 4.7kω resistor, the output voltage range is 0.77v to 4.57v over the resistor range of the 50kω resistor.
conclusionsthe ds1847 and ds1848 have many features that would be useful in industrial control applications. the variable resistors could easily replace a mechanical potentiometer and provide additional features. the ds1847 and ds1848 are able to perform multiple functions in one small package including temperature compensation. the ds1847 and ds1848 can be used standalone or with a microcontroller. to discuss your application, email applications support at mixedsignal.apps@dalsemi.com.

微软Surface Duo软件会有大改进 支持3D深度相机
低压耐压测试仪测试步骤
基于结温保护的LED驱动电路设计
半导体设备厂商DE&T和ELP取得FPCB更换系统专利
汽车充电桩运营管理平台的设计与应用
介绍DS1847用于工业控制-Introduction of
工业互联网平台加速了石化行业数字化转型步伐
一加科技进军智能家居产品,首款智能家居产品将是智能电视
环旭电子与Asteelflash拟约4.5亿美元并购FAFG100%股权
中国通信业全面深化改革、通信央企做强做优做大的历史新篇
MMA766OFC加速度计在移动电话中的应用
被华为先发制人了?小米6:还要再等一个月值得等待
双核单片机之初体验
想尽快上手FPGA,FPGA开发流程了解一下
介绍一种友恩充电器芯片U6101
芯片初创公司Pliops完成6500万美元融资
各种形式滤波电路分析
工信部发正式牌照鼓励移动通信创新还要促进工业互联网平台建设
人工智能元老发声:IBM在说谎,Watson就是一个骗局
光纤收发器测试流程和连接方式