abstract: in many applications, particularly in automotive application, limiting the transducer output to some predefined values, also referred to as output clipping, can serve as an important diagnostic tool. the max1455 low-cost high-performance signal conditioner has the clipping function built in. a simple method of implementing an external output clipping function to the max1452 signal conditioner has been presented here. this is accomplished by adding few resistors and utilizing the on-chip uncommitted op amp.
the max1452 (figure 1) output signal is an analog voltage that can range from the vdd rail to the vss rail. the part can be configured to limit (clip) its output voltage to aid in system level diagnostics in sensor applications. this capability can detect open or short circuits caused by wiring or connector falures, and can detect sensor failures.
forced clipping can be accomplished by using the integrated uncommitted op-amp and a few external resistors. the clip voltage range can be set to be symmetrical or asymmetrical to the supply voltages. the clip voltages are fully ratiometric to the supply voltages, maintaining the ratiometric performance of the system.
figure 1. the max1452 schematic.
the output clip voltages are referred to as clip-top for limiting at the upper voltage range near vdd, and clip-bot for limiting at the lower voltage range near vss. this can be seen graphically in figure 2 for three different clip-range settings. all signals that would normally result in an output voltage greater than clip-top or lower than clip-bot will be truncated at the clip level. over-range signals that would normally result in a saturated high or low output voltage would result in a clipped output at the clip voltage setting. no normal or over-range operation of the circuit can produce a voltage output in-between the clip voltage and the power-supply rail. system fault conditions (a short in wires to sensor, open wires or connections) will produce voltage signals beyond the clip voltage and near the supply-rail voltage.
figure 2. various output diagnostic clip settings.
a typical application diagram is shown in figure 3. the sensor assembly contains a pressure or force transducer and the max1452 signal conditioning ic. a wire-harness joins the sensor assembly to the primary electronic control unit (ecu). the ecu provides the power-supply voltage (5v typical) to the sensor and receives the analog voltage signal from the sensor. the three harness wires are often bundled with other wires and may pass through several connector systems between the sensor and the ecu. it is desirable to detect an open circuit in the wires or connectors so that the ecu can take appropriate action. this action may consist of shutting down a subsystem, disregarding all measurements on the suspect line, or activating warning lights to indicate the fault condition.
figure 3. typical sensor wiring configuration.
it is common practice to use a pull-up or pull-down resistor on the vout line in the ecu that will pull the line to a defined state when the vout line is an open circuit, as shown in figure 2. values for rpu or rpd of 2.2kω to 10kω have been used. when the vout line is an open circuit the resistor pulls the line to a supply-rail and keeps it stable at that value. without the clip diagnostic function, a voltage on vout of 0v would be considered a no-load condition. by limiting the normal operating output of the sensor to values that are slightly away from the supply-rail voltages, a supply-rail voltage is then considered an anomalous signal and a fault condition (i.e., an open circuit in the vout line).
the three resistors that form the clip function are r1, r2, and r3, as shown in figure 4. by selecting values for these resistors, precise clip voltages can be obtained. the op-amp is configured as a voltage follower which provides the drive capability for vout and buffers the resistor network from changing loads on the vout line. symmetrical clipping occurs when r1=r2. setting r1 and r2 to different values controls asymmetrical clipping. r3 controls how close the output signal vout swings toward each rail. table 1 shows three different clip range conditions created with three different resistor settings.
figure 4. creating clip-high and clip-low diagnostic voltage limiting.
table 1. output clip voltage settings with vdd = 5.0vdc
r1 (ω)
r2 (ω)
r3 (ω)
output clip high (v)
output clip low (v)
10k
10k
208
4.90
0.10
10k
10k
555
4.75
0.25
10k
10k
1.25k
4.50
0.50
10k
5k
588
4.50
0.25
酒厂气体报警器的使用与维护
汽车毫米波雷达测试方案
华为65WUSBPD充电器拆解 整机的用料和做工依然保持业界领先水准
什么是特洛伊木马技术
用FPGA芯片实现高速异步FIFO的一种方法
MAX1452 Diagnostic Clip Circui
比原链正式启动全球开发者大赛,在区块链技术大赛中的优秀团队将会获得200万BTM
CAN总线错误帧基础知识及排查分析技术
一文看懂软性线路板行业发展趋势
螺旋板换热器是一种节能的热交换设备,它的特点分析
粮食水分检测仪的详细介绍
一加3T欧美广告“舔”爱,看得我面红耳赤
单片机教程二:单片机存储器结构
网友:小米6来不来无所谓!四个月不降价,最保值的小米手机
远程医疗与智能监护产品
DC-DC BOOST空载时输入电流的计算公式
不锈钢等离子清洗效果评估|钢板表面油脂污染情况检测方案表面油脂污染度清洁度检测
如何定制Arduino零件
英飞凌科技推出XDP™数字电源平台LED应用系列的新成员XDPL8221
防爆电气设备的标志是什么